Product · Liquid Cooling
1800 Liquid Cooling Container (L1800C45) L1800C45DR220 45ft 1800 kW Liquid Cooling container · dual loop · GPU 36–45 °C · in-row CW 10/15 °C · no UPS · up to 220 kW/rack

The one you buy when you're
out of floor, not out of power.

L1800C45 is the line’s density ceiling: 1,800 kW and up to 220 kW/rack in the same 45 ft High Cube as L1240, dual loop, UPS left outside. Buy it when the pad already has distribution. Expansion blocks: 90 days ex-works.

Runs CIOS · →
1800 kW
IT Capacity
up to 220 kW/rack
Power Density · R220
Dual loop
GPU 36–45 °C · in-row CW 10/15 °C
90 d EXW
From down payment
01
The one thing

220 kW/rack in the same 45 ft shell — UPS stays outside.

The line tops out here. L1800C45 is the only liquid SKU rated R220 — 220 kW/rack — for GB300 NVL72 / B300 HGX in a 45 ft shell. Omitting UPS is not a missing part: the site already paid for power, so the box does not bill you twice. Dual loops (GPU 36–45 °C, in-row CW 10/15 °C) stay in the same factory-tested enclosure.

Form Factor
45-ft High Cube container
SKU ID
L1800C45DR220
IT Capacity
1,800 kW
Cooling
Dual loop · GPU 36–45 °C · in-row CW 10/15 °C
UPS
External — UPS / battery / PDC outside the box
Density
Up to 220 kW/rack (R220)
Status
Available
Lead Time
90 d EXW from down payment · expansion 90 d EXW

Roadmap A separate MDCX power module (UPS / battery / PDC) is in development for sites where the boundary must sit outside the compute enclosure.

L1800C45 liquid cooling container cutaway poster
L1800C45 — dual loop: GPU warm water 36–45 °C and chilled-water in-row CW 10/15 °C.

Cold plate is the entry ticket for SXM-class density. Why Liquid Cooling →

02
Versus the rest of the line

Not L1240: you already have power. Not L450: you need the whole 45 ft of racks.

L1240 is the empty-pad buy — UPS in the box, 150 kW/rack. L450 is the 20 ft first placement at a higher cost per kW. L1800C45 is neither: same 45 ft footprint as L1240, 560 kW more IT, 70 kW more per rack, and the power plant stays in the yard.

03
Walk through it

Explore L1800C45 in 3D

Explore the 45 ft high-density Liquid Cooling container — gullwing doors and rack access.

MDCX L1800C45 liquid cooling container

The OpenUSD reference model is published in the annex of the L1800C45 Reference Design. Heavy USD is explicit download only. Specs: USD output.

Ready to specify a block?
Talk to sales, or model economics in TCO first.

Single-line power, cooling loops, ratings, and downloads for engineers.

Questions

How is L1800C45 different from L1240C45?

L1800C45 (L1800C45DR220) is 1,800 kW in the same 45 ft shell, dual loop, up to 220 kW/rack, with UPS outside. L1240C45 is 1,240 kW, single 26 °C loop, UPS inside.

What is the maximum rack density of L1800C45?

Up to 220 kW per rack (R220) — the density ceiling of the Liquid Cooling line.

How long is delivery for L1800C45?

First delivery is 90 days ex-works from receipt of down payment. Expansion blocks: 90 days ex-works.

Specifications updated August 2026 · design targets, site conditions apply.